Home » Products »

PE Insulated, LSZH Sheathed, Overall Screened And Armoured Instrumentation Cables (Multipair)

Delivery term:The date of payment from buyers deliver within days
  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shandong

  • Validity to:

    Long-term effective

  • Last update:

    2017-08-16 07:51

  • Browse the number:

    144

Send an inquiries
Company Profile
Universal Cables Limited
Contactaixin:

sdhuanyu(Mr.)  

Email:

telephone:

phone:

Arrea:

Shandong

Address:

1building, Shuntai Square, High-Tech Zone, Jinan City, China

Website:

http://www.ue-cable.com/ http://sdhuanyu.hyunism.com/

Product details


Supplying you with customized pe insulated, lszh sheathed, overall screened and armoured instrumentation cables (multipair), it is one of the reliable pe insulated, lszh sheathed, overall screened and armoured instrumentation cables (multipair) manufacturers and suppliers, welcome to wholesale our products at good price from our factory.



PE Insulated, LSZH Sheathed, Overall Screened & Armoured Instrumentation Cables (Multipair)



RE-2Y(St)HSWAH 90°C / 300V








STANDARDS




Basic design to EN 50288-7




APPLICATION




Instrument cable minimizes noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations.



FIRE PERFORMANCE




















Flame Retardance (Single Vertical Wire Test)




EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);



CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*




Reduced Fire Propagation   (Vertically-mounted bundled wires & cable test)




EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4




Halogen Free




IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;



CEI 20-37/2-1 ; BS 6425-1*




No Corrosive Gas Emission




IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;



CEI 20-37/2-2 ; BS 6425-2*




Minimum Smoke Emission




IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;



CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*




No Toxic gases




NES 02-713; NF C 20-454




Sunlight Resistance




UL 1581 section 1200




Oil Resistance




ICEA S-73-532**



Note: Asterisk * denotes superseded standard, **Test temperature +60°C, duration 4h. Retention: min 60% of tensite strength/min.60% of elongation.






































VOLTAGE RATING




300V




CABLE CONSTRUCTION








Conductor:




Annealed copper solid or plain copper stranded to IEC 60228 Class 2.




Insulation:




PE compound, EN 50290. 2-23.




Pair:




Two insulated conductors uniformly twisted together with a lay not exceeding 100mm




Binder tape:




PETP transparent tape




Overall Screen:




Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm²




Inner Sheath:




LSZH(Low Smoke Zero Halogen) sheath




Amouring:




Galvanized steel wire armour




Outer Sheath:




Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4  as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.




COLOUR CODE








Insulation:




Black / White, continuously numbered on white core(1, 2..)for multipair.




Outer Sheath:




Black or blue for intrinsically safe systems




Physical AND THERMAL PROPERTIES








Temperature Range During Operation (Fixed State):




-30°C – +90°C




Temperature Range During Installation (Mobile State):




-20°C – +50°C




Minimum Bending Radius:




10 X Overall Diameter



CONSTRUCTION PARAMETERS


























































































































Cable Code




RE-2Y(St)HSWAH




No. of



Pairsx2



xCross



Section




Nominal



Insulation



Thick



-ness




Nominal



Inner Sheath



Thick



-ness




Nominal



Overall



Diameter



Over



Inner



Sheath




Nominal



Armour



Wire



Diameter




Nominal



Outer



Sheath



Thick



-ness




Nominal



Overall



Diameter




Approx.



Weight








No.x2xmm2




mm2




mm




mm




mm




mm




mm




kg/km




0.5mm2, Multipair




RE-2Y(St)HSWAH 2P0.5




2x2x0.5




0.35




0.9




7.6




0.9




1.3




12.0




262




RE-2Y(St)HSWAH 4P0.5




3x2x0.5




0.35




0.9




8.8




0.9




1.4




13.4




325




RE-2Y(St)HSWAH 5P0.5




4x2x0.5




0.35




1.0




9.8




0.9




1.4




14.4




375




RE-2Y(St)HSWAH 6P0.5




5x2x0.5




0.35




1.0




10.6




0.9




1.4




15.2




411




RE-2Y(St)HSWAH 8P0.5




8x2x0.5




0.35




1.0




11.3




0.9




1.4




15.9




473




RE-2Y(St)HSWAH 10P0.5




10x2x0.5




0.35




1.1




12.9




0.9




1.5




17.7




537




RE-2Y(St)HSWAH 12P0.5




12x2x0.5




0.35




1.1




13.5




0.9




1.5




18.3




576




RE-2Y(St)HSWAH 16P0.5




16x2x0.5




0.35




1.1




15.2




0.9




1.5




20.0




824




RE-2Y(St)HSWAH 20P0.5




20x2x0.5




0.35




1.2




16.9




0.9




1.6




21.9




949




RE-2Y(St)HSWAH 24P0.5




24x2x0.5




0.35




1.2




18.3




1.25




1.6




24.0




1030




0.75mm2, Multipair




RE-2Y(St)HSWAH 2P0.75




2x2x0.75




0.38




0.9




8.5




0.9




1.4




13.1